| Failure | Symptom | Primary cause | Action |
| Capacity loss, coarsening product | Output down, fineness drifts |
Roll and ring wear; blade wear; duct build-up; fan volume loss |
Check air circuit first |
| Vibration, abnormal noise |
Knocking, rising vibration |
Uneven feed; foreign matter; roller assembly wear; loose bolts |
Stop and inspect |
| Bearing overheating | High temperature, dark oil |
Low or degraded oil; seal leak; dust ingress; misalignment |
Stop and inspect |
| Duct and cyclone blockage | Pressure swings, output falls | High moisture; excess return load; air leakage |
Pressure-test circuit |
| Dust at flanges | Powder at doors and flanges |
Aged gaskets; low negative pressure; worn airlock valve |
Plan; compliance item |
| Reducer oil leak | Seepage, low oil level | Aged seals; loose bolts; blocked breather |
Check breather first |

| Level | Scope | Escalate when |
| Maintenance | Bolts, breather, duct cleaning, oil and moisture checks |
The same condition recurs within one interval |
| Parts replacement | Rolls and rings, classifier blades, gaskets, seals, airlock valves, bearings |
Measured wear reaches limits before schedule |
| System modification or replacement |
Persistent air-volume loss, repeated misalignment, capacity shortfall, chronic leakage |
Annual cost of the first two levels approaches the amortised cost of the third |

| Dimension | Conventional Raymond mill | CLRM enhanced roller mill |
| Grinding assembly | Suspended roller, fixed load |
Revised roller layout; pressure +10%, grinding area +15–20% vs. a conventional Raymond mill |
| Vibration path | Damping at base only | Damping at base, volute duct, main unit body, grinding assembly |
| Classifier | Blade type, narrow range |
Cage-type impeller, VFD, 80–425 mesh / 180–33 micron |
| Sealing | Single-stage | Superimposed multistage seal; lubrication interval extended beyond the conventional single-shift cycle |
| Airflow principle | Closed loop, positive-negative pressure |
Unchanged: closed loop, positive-negative pressure |